Search In this Thesis
   Search In this Thesis  
العنوان
Evaluation of Some Physical and Mechanical Properties of Three Bio-ceramic Sealers :
المؤلف
Elshazly, El-Shimaa Abdelkrim Nagy Abdelrahman.
هيئة الاعداد
باحث / الشيماء عبد الكريم ناجي عبد الرحمن الشاذلي
مشرف / مجدي محمد علي
مشرف / داليا علي احمد مقرب
مشرف / ريم جمال حسن
مناقش / محمد عبد العزيز سهيل
مناقش / شمس واعظ أمجد علي
الموضوع
Dental ceramics. Ceramics. Dental Porcelain. Biocompatible Materials. Surface Properties.
تاريخ النشر
2023.
عدد الصفحات
101 p. :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
طب الأسنان
تاريخ الإجازة
10/9/2023
مكان الإجازة
جامعة المنيا - كلية طب الأسنان - خواص المواد الحيوية
الفهرس
Only 14 pages are availabe for public view

from 117

from 117

Abstract

One of the principal objectives in endodontic treatment is to give sealers properties that satisfy all Grossman’s requirements.This concentrate on assessed the stream, film thickness, starting and last setting time, water sorption and dissolvability, push out security strength and microleakage of three business BCS_MTA as per ISO particulars no 6876 guidelines.
For the stream test, a 0.5 ml sealer was put on a glass chunk and covered with another glass slab,20g weight, of similar aspects was put over the sealer. Then a 100g burden was halfway applied to the section for 10min. from that point forward, the progression of the sealer plates was estimated utilizing a computerized caliper. For the film thickness two glass pieces 5mm thick were utilized. A 0.5ml sealer was put on the focal point of one glass piece. The other section was situated halfway to the sealer. After 180 sec post blending, a heap of 15kg was applied on top of the chunk. Ten minutes subsequent to blending, the heap was eliminated and the complete thickness of the two sections and the sealer film was estimated with a computerized caliper. The distinction between the two estimations was viewed as the film thickness.
For setting time, tests were ready by utilizing a split metallic shape (10 x 2) mm. Wet tissue was utilized to cover glass slap then the shape was put ready to move on. The Gilmore gadget with an openly moved 100g±0.05 weight fixed to, 2mm gruff tip indenter was utilized to gauge introductory setting time and 456.5g±0.05 weight fixed to 1.0mm obtuse tip indenter for conclusive setting time that was recorded from the finish of blending till neglected to make noticeable space with its particular weight and indenter.
For water sorption and solvency, split Teflon molds of (20 x 1.5) mm were utilized for test readiness. Each example in each gathering was weighed multiple times, first starting estimation m0, second after submersion in 50ml distalled water for 24h At last, after parching m2. Water sorption and dissolvability were estimated from the accompanying conditions (m1-m2/V, m0-m2)/v separately.
For the push out bond strength test, a 21 single established single waterway teeth were utilized. After execution, cleaning and molding of the root channel, the roots were covered by 2 layers of nail stain and set in acrylic pitch blocks. Then, at that point, the root channels were obturated and put away at 100 percent stickiness for 7 days. A 3mm thickness cuts of cervical piece of the root was segmented evenly utilizing jewel plates. Each example was set in the stacking apparatus. The test was directed utilizing a 1mm breadth unclogger connected to the general testing machine at a crosshead speed of 0.5mm/min. The greatest burden at which the example was ousted was recorded and the bond strength was determined in MPa.
For microleakage test, the remainder of roots utilized in push out bond strength test were utilized in this test covered with nail stain 2mm more limited than the peak then the uncovered surfaces of the roots were suspended in newly pre-arranged 1% methylene blue stain for 24hr at 37°C 100 percent dampness. After that roots were washed for 15min under running faucet water. The nail stain layers were rejected off and the roots were separated longitudinally into equal parts lined up with the long hub with jewel circle. The profundity of color infiltration was inspected under a stereomicroscope and the maximum profundity of entrance was recorded.
For the stream, test bunch I showed the most elevated mean worth and the least measurably huge mean worth was bunch II. For the film thickness, the most elevated genuinely critical mean worth was kept in bunch II while the least mean worth was kept in bunch III.
For starting setting time, the most elevated measurably huge mean worth was kept in bunch I. The least measurably huge mean worth was kept in bunch III. For conclusive setting time, bunch I couldn’t set as long as one month. Bunch III was the briefest measurably critical mean worth. For water sorption, the most noteworthy measurably critical mean worth was kept in bunch II while the least genuinely huge mean worth was kept in bunch I. for water solvency, The most noteworthy mean worth was kept in bunch III while the least genuinely critical mean worth was kept in bunch I.
For push out bond strength, the most noteworthy genuinely huge mean worth was kept in bunch I while the least measurably critical mean worth was kept in bunch II. For microleakage test, the most noteworthy genuinely critical mean worth was kept in bunch II while the least measurably huge mean worth was kept in bunch III.
Ends
Inside the impediments of the current review the accompanying can be closed:
1. flow and film thickness upsides of the tried sealers satisfied the ISO details no 6876 prerequisites with the exception of Ceramoseal BC sealer.
2. Setting season of all sealers tried didn’t satisfied their assembling announcement.
3. Thorough upsides of the water sorption and dissolvability of all tried sealers didn’t satisfied the ISO particulars no 6876 prerequisites.
4. Endoseal MTA sealer display the best ability to fix property contrasting with other tried sealers
Recommendations
• Further researches should be included regarding setting time of sealers.
• Further researches should be included regarding adaptability of sealers.
• Regaeding the 3 sealers tested in this study, Endoseal MTA sealer exhibited the properties and recommended to used.