Search In this Thesis
   Search In this Thesis  
العنوان
Mesially placed implant as an abutment for extracoronal attachment mandibular distally extension removable partial denture radiographic evaluation /
المؤلف
El-Gamal, Mohamed El-Sayed El-Badawy Mohamed.
هيئة الاعداد
باحث / محمد السيد البدوي محمد عبدالفتاح الجمل
مشرف / محمد محمد عبدالخالق
مشرف / صلاح عبدالفتاح حجازي
مشرف / أشرف أنور جبريل
مشرف / أحمد صبحي سالم
الموضوع
Partial dentures, Removable. Denture attachments.
تاريخ النشر
2016.
عدد الصفحات
198 p. :
اللغة
الإنجليزية
الدرجة
الدكتوراه
التخصص
طب الأسنان
تاريخ الإجازة
01/01/2016
مكان الإجازة
جامعة المنصورة - كلية طب الأسنان - Removable Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 198

from 198

Abstract

Purpose: To study radiographically the effect of tooth implant splinting concept as aprosthetic treatment planning for mandibular distal extension precision attachment RPD. Materials and Methods: Five patients of completely edentulous maxillary arch against mandibular bilateral distal extension ridges were selected for mesial implant placement at first premolar area utilizing 2 stage surgical protocol. After 3 months the healing abutment was attached correctly to fixture. Full crown preparation for tooth abutment then implant level impression was made. On the cast preparation of implant abutment by milling technique was done. Splinted crowns with patrix of extracoronal attachment were constructed. Altered cast impression technique was made utilizing metallic RPD framework. Crestal alveolar bone height change of splinted abutment and distal extension ridge were radiographically evaluated immediately before and after 6, 12 months of denture insertion. Results: There is no significant difference in crestal alveolar bone height change when comparing the mesial surface to the distal surface of abutment tooth. Alternatively, the distal surface of implant abutment exhibited a significant increase in crestal alveolar bone resorption compared to mesial one along the interval period of study. Distal part of the ridge exhibited greater crestal alveolar bone resorption than mesial part. Abutment teeth were found less alveolar bone resorption compared to either implant or ridge after 12 months of denture insertion.Conclusion: 1) The splinted abutment canine was preserved with implant assisted vario-stud snap extracoronal attachment RPD regarding alveolar bone height change. 2) Although vario-stud snap extracoronal attachment with shear distributor that direct force along the long axis of splinted abutment, tooth implant splinting concept was not to preserve crestal implant alveolar bone from resorption.